Heating, ventilating and air-conditioning system energy demand coupling with building loads for office buildings.

De Montfort University Open Research Archive

Show simple item record

dc.contributor.author Korolija, Ivan
dc.date.accessioned 2012-01-13T09:45:16Z
dc.date.available 2012-01-13T09:45:16Z
dc.date.issued 2011
dc.identifier.uri http://hdl.handle.net/2086/5501
dc.description.abstract The UK building stock accounts for about half of all energy consumed in the UK. A large portion of the energy is consumed by nondomestic buildings. Offices and retail are the most energy intensive typologies within the nondomestic building sector, typically accounting for over 50% of the nondomestic buildings’ total energy consumption. Heating, ventilating and air conditioning (HVAC) systems are the largest energy end use in the nondomestic sector, with energy consumption close to 50% of total energy consumption. Different HVAC systems have different energy requirements when responding to the same building heating and cooling demands. On the other hand, building heating and cooling demands depend on various parameters such as building fabrics, glazing ratio, building form, occupancy pattern, and many others. HVAC system energy requirements and building energy demands can be determined by mathematical modelling. A widely accepted approach among building professionals is to use building energy simulation tools such as EnergyPlus, IES, DOE2, etc. which can analyse in detail building energy consumption. However, preparing and running simulations in such tools is usually very complicated, time consuming and costly. Their complexity has been identified as the biggest obstacle. Adequate alternatives to complex building energy simulation tools are regression models which can provide results in an easier and faster way. This research deals with the development of regression models that enable the selection of HVAC systems for office buildings. In addition, the models are able to predict annual heating, cooling and auxiliary energy requirements of different HVAC systems as a function of office building heating and cooling demands. For the first part of the data set development used for the regression analysis, a data set of office building simulation archetypes was developed. The four most typical built forms (open plan sidelit, cellular sidelit, artificially lit open plan and composite sidelit cellular around artificially lit open plan built form) were coupled with five types of building fabric and three levels of glazing ratio. Furthermore, two measures of reducing solar heat gains were considered as well as implementation of daylight control. Also, building orientation was included in the analysis. In total 3840 different office buildings were then further coupled with five different HVAC systems: variable air volume system; constant air volume system; fan coil system with dedicated air; chilled ceiling system with embedded pipes, dedicated air and radiator heating; and chilled ceiling system with exposed aluminium panels, dedicated air and radiator heating. The total number of models simulated in EnergyPlus, in order to develop the input database for regression analysis, was 23,040. The results clearly indicate that it is possible to form a reliable judgement about each different HVAC system’s heating, cooling and auxiliary energy requirements based only on office building heating and cooling demands. High coefficients of determination of the proposed regression models show that HVAC system requirements can be predicted with high accuracy. The lowest coefficient of determination among cooling regression models was 0.94 in the case of the CAV system. HVAC system heating energy requirement regression models had a coefficient of determination above 0.96. The auxiliary energy requirement models had a coefficient of determination above 0.95, except in the case of chilled ceiling systems where the coefficient of determination was around 0.87. This research demonstrates that simplified regression models can be used to provide design decisions for the office building HVAC systems studied. Such models allow more rapid determination of HVAC systems energy requirements without the need for time-consuming (hence expensive) reconfigurations and runs of the simulation program. en
dc.description.sponsorship This work was funded by EU-FP6 Marie Curie Actions - Marie Curie Research Training Networks. Contract Number: MRTN-CT-2006-033489 Project: CITYNET – Development of an integrated urban management tool en
dc.language.iso en en
dc.publisher De Montfort University en
dc.subject office buildings en
dc.subject energy demand en
dc.subject HVAC system en
dc.subject energy consumption en
dc.subject VAV en
dc.subject CAV en
dc.subject fan-coils en
dc.subject chilled ceiling en
dc.subject energy efficiency en
dc.subject energy modelling en
dc.subject energy performance en
dc.subject EnergyPlus en
dc.subject cooling requirements en
dc.subject heating requirements en
dc.subject regression model en
dc.title Heating, ventilating and air-conditioning system energy demand coupling with building loads for office buildings. en
dc.type Thesis or dissertation en
dc.publisher.department Institute of Energy and Sustainable Development en
dc.publisher.department Faculty of Technology en
dc.type.qualificationlevel Doctoral en
dc.type.qualificationname PhD en


Files in this item

This item appears in the following Collection(s)

Show simple item record